Analisa Harmonisa Transformator Satu Fasa Berbeban Motor Arus Searah Melalui Rectifier dan Simulasi Filter Pasif Berbasis MATLAB di Laboratorium Program Studi Teknik Elektro Fakultas Teknik Universitas Kristen Indonesia

Dangin, Helda Oktavianti and Silalahi, Eva Magdalena and Purba, Robinson (2023) Analisa Harmonisa Transformator Satu Fasa Berbeban Motor Arus Searah Melalui Rectifier dan Simulasi Filter Pasif Berbasis MATLAB di Laboratorium Program Studi Teknik Elektro Fakultas Teknik Universitas Kristen Indonesia. Lektrokom: Jurnal Ilmiah Program Studi Teknik Elektro, 6 (2). pp. 37-49. ISSN 2686-1534

[img] Text
AnalisaHarmonisaTransformatorSatuFasaBerbebanMotorArus.pdf

Download (1MB)
Official URL: http://ejournal.uki.ac.id/index.php/lektrokom/inde...

Abstract

Penelitian ini menganalisis harmonisa transformator satu fasa yang dibebani dengan Motor Arus Searah (MAS) dan penyearah dengan menggunakan pendekatan metode kuantitatif. Tujuan dari penelitian ini adalah untuk mengidentifikasi nilai Total Harmonic Distortion untuk arus (THDi) pada transformator dan merancang filter pasif guna mengurangi tingkat harmonisa apabila tidakmemenuhi standar. Hasil penelitian menunjukkan bahwa hasil pengukuran, diperoleh THDi 31,01% pada transformator beban nol, pada transformator dengan beban MAS dengan penyearahsetengah gelombang, THDi sebesar 79,35%, dan pada transformator berbeban MAS denganpenyearah gelombang penuh, THDi sebesar 46,40%, yang melebihi standar IEEE 519-2014. Hasil simulasi filter pasif single tuned LC menunjukkan bahwa pada transformator berbeban MASdengan penyearah setengah gelombang mengalami penurunan tingkat harmonisa dari nilai THDi 79,35% sebelum menggunakan filter, menjadi 1,04% setelah menggunakan filter dan memenuhi standar IEEE 519-2014. Tingkat harmonisa dari transformator berbeban MAS dengan penyearahgelombang penuh, sebelum difilter, THDi 46,40%, namun setelah difilter, THDi 37,98%, masihmelebihi standar IEEE 519-2014. Kata Kunci: filter pasif single tuned, harmonisa, standar IEEE 519-2014, transformator. / This study analyzed the harmonics of single-phase transformers loaded with Direct Current Motor (MAS) and rectifier using quantitative method approach. The purpose of this study was toidentify the Total Harmonic Distortion (THDi) value in transformers and design passive filters toreduce harmonic levels if they do not meet the standards. The results showed that themeasurement results, obtained THDi 31.01% in zero-load transformers, in transformers withMAS load with half-wave rectifiers, THDi by 79.35%, and in MAS load transformers with full- wave rectifiers, THDi by 46.40%, which exceeded IEEE 519-2014 standards. The results of thesingle tuned LC passive filter simulation showed that the MAS loaded transformer with a half- wave rectifier decreased harmonic level from the THDi value of 79.35% before using the filter, to1.04% after using the filter and met IEEE 519-2014 standards. The harmonic level of MASloaded transformer with full wave rectifier, before filtering, THDi 46.40%, but after filtering, THDi 37.98%, still exceeds IEEE 519-2014 standard. Keywords: single tuned passive filter, harmonic, IEEE 519-2014 standard, transformer

Item Type: Article
Subjects: TECHNOLOGY
Depositing User: Mr Sahat Maruli Tua Sinaga
Date Deposited: 18 Dec 2024 03:39
Last Modified: 18 Dec 2024 03:39
URI: http://repository.uki.ac.id/id/eprint/17888

Actions (login required)

View Item View Item