Simanjuntak, Irene Vista and Tampubolon, Sudarno P (2022) Pengaruh Variasi Agregat Kasar Penyusun Beton Porous Terhadap Kuat Tekan dan Porositas Beton. Jurnal Rekayasa Teknik Sipil dan Lingkungan, 3 (1). pp. 1-10. ISSN 2722-0230
![]() |
Text
PengaruhVariasiAgregatKasarPenyusunBetonPorous.pdf Download (1MB) |
![]() |
Text (Hasil_Turnitin)
HasilTurnitinPengaruhVariasiAgregatKasarPenyusunBetonPorous.pdf Download (3MB) |
Abstract
Penggunaan beton tradisional yang berkelanjutan telah menghasilkan lapisan kedap air yang lebih tebal, mencegah air hujan masuk ke tanah dan meningkatkan limpasan permukaan. Akibatnya, permukaan air turun selama musim hujan, dan banjir terjadi. Salah satu inovasi untuk mengantisipasi atau mengatasi permasalahan tersebut adalah dengan menggunakan material terbarukan seperti beton aerasi. Perkerasan beton permeabel dimaksudkan untuk mengurangi genangan air di jalan. Dengan menghilangkan agregat halus, beton berpori menjadi sederhana, beton ringan. Rongga yang saling berhubungan menghasilkan tingkat porositas yang tinggi. Beton berpori biasanya memiliki sedikit atau tidak ada agregat halus dan pasta semen yang cukup untuk melapisi permukaan agregat kasar. Karena porositas yang meningkat, kuat tekan beton yang tidak diampelas lebih rendah daripada beton normal konvensional. Beton bebas pasir memiliki kekuatan tarik dan lentur yang jauh lebih rendah daripada beton konvensional. Dalam penelitian ini digunakan dua agregat kasar dengan ukuran nominal maksimum 12,5 mm dan 6,7 mm sebagai batuan split dengan bobot masing-masing 1,123 kg/m3 dan 2,63 kg/m3. Faktor air semen (FAS) 0,35 dan volume air 0,35 kg menggunakan semen Portland tipe 1 dengan kuantitas 389,6 kg/m3. Benda uji berupa silinder beton dengan diameter 80 mm dan tinggi 16 mm. Setelah mencelupkan benda uji ke dalam bak berisi air, masing-masing campuran memiliki tiga benda uji. Kata kunci: Beton porous, daerah resapan air, kuat tekan, infiltrasi /The continued use of traditional concrete has resulted in a thicker layer of waterproofing, preventing rainwater from entering the ground and increasing surface run off. As a result, the water table drops during the rainy season, and flooding occurs. One of the innovations to anticipate or overcome these problems is using renewable materials such as aerated concrete. Permeable concrete pavements are intended to reduce puddles on the street. By omitting fine aggregate, porous concrete is simple, lightweight concrete. The interconnected cavities result in a high level of porosity. Porous concrete usually has little to no fine aggregate and enough cement paste to coat the coarse aggregate's surface. Due to the increased porosity, the compressive strength of un-sanded concrete is lower than that of conventional normal concrete. Sand-free concrete has much lower tensile and flexural strength than conventional concrete. In this study, two coarse aggregates with nominal maximum sizes of 12.5 mm and 6.7 mm were used as split rocks with weights of 1.123 kg/m3 and 2.63 kg/m3, respectively. Hence, a FAS of 0.35 and a water volume of 0.35 kg using Portland cement type 1 with a quantity of 389.6 kg/m3. The test object is a concrete cylinder with a diameter of 80 mm and a height of 16 mm. After immersing the specimen in a tub of water, each mixture has three specimens. Keywords: Porous concrete, water catchment area, compressive strength, infiltration
Item Type: | Article |
---|---|
Subjects: | TECHNOLOGY |
Depositing User: | Ms Rosaliana Wati |
Date Deposited: | 10 Jul 2025 12:13 |
Last Modified: | 10 Jul 2025 12:13 |
URI: | http://repository.uki.ac.id/id/eprint/19541 |
Actions (login required)
![]() |
View Item |