Analisis Ketahanan Pompa dengan Penggerak Arus Listrik Direct Current

Samosir, Rahmad and Pane, Medyawanti and Turnip, Kimar and Parluhutan, Rio (2022) Analisis Ketahanan Pompa dengan Penggerak Arus Listrik Direct Current. Jurnal Teknik Mesin Indonesia (JTMI), 17 (1). pp. 12-18. ISSN 2597 7563

[img] Text
AnalisisKetahanapompadenganpPenggerakArus.pdf

Download (780kB)
[img] Text
Hasil_TurnitinAnalisisKetahanapompadenganpPenggerakArus.pdf

Download (1MB)
Official URL: http://ojs3.bkstm.org/index.php/jtmi/index

Abstract

gan arus DC sangat potensial karena dapat menggunakan listrik langsung dari panel surya, akan tetapi masyarakat umum belum mengetahui keandalan pompa tersebut. Untuk mengetahui keandalan pompa tersebut, dilakukan kajian ini. Berdasarkan pengujian yang dilakukan untuk mengetahui ketahanan pompa menggunakan pompa DC dengan spesifikasi sebagai berikut: daya masimum 180 W, head maksimum 15 m, kapasitas maksimum 1,5 m3 /jam dengan 12 V. Dari hasil pengujian selama 5 x 24 jam dengan head 4,9 m diperoleh hasil yaitu pada voltage 12,04 V dan 4,09 A didapat kapasitas pompa yaitu 23 liter/menit, daya pompa 50,7 W. Pada tegangan 7,7 V dan 6,02 A didapatkan kapasitas pompa yaitu 10 liter/menit, daya pompa 46,4 W. Pada tegangan 12,06 V dan 4,1 A didapatkan kapasitas pompa yaitu 20 liter/menit daya pompa 49,4 W. Sehingga dapat diambil kesimpulan bahwa dari hari pertama sampai hari ke tujuh, performa pompa dapat dinilai hanya mengalami sedikit perubahan dari 23 liter/menit menjadi 20 liter/menit. Kata kunci: pompa, arus DC, ketahanan. / When DC water pumps have been widely produced, they are still rarely used by the general public. The use of DC current is very potential because it can use electricity directly from solar panels, but the general public does not yet know the reliability of the pump. To determine the reliability of the pump, so this research were conducted. The maximum capacity is 1.5 m3 /hour with 12 V. From the test results for 5 x 24 hours with a head of 4.9 m, the results obtained are at a voltage of 12.04 V and 4.09 A, the pump capacity is 23 liters/minute, pump power is 50.7 W. At a voltage of 7.7 V and 6.02 A, the pump capacity is 10 liters/minute, the pump power is 46.4 W. At a voltage of 12.06 V and 4.1 A, the pump capacity is 20 liters/minute, the pump power is 49.4 W. So it can be concluded that from the first day to the seventh day the pump performance can be judged to have only experienced a slight change from 23 liters/minute to 20 liters/minute. Keywords: pump, direct current (DC), endurance.

Item Type: Article
Subjects: TECHNOLOGY
Depositing User: Ms Ernawanty Situmorang
Date Deposited: 20 Feb 2025 02:22
Last Modified: 20 Feb 2025 02:26
URI: http://repository.uki.ac.id/id/eprint/18377

Actions (login required)